Zarinshenas, Reza and Destrampe, Eric D. and Rose, William Nicholas (2020) Plasmapheresis for the Treatment of Iatrogenic Antithrombin Excess as a Result of Spuriously Low Antithrombin Activity Measurements. Case Reports in Critical Care, 2020. pp. 1-3. ISSN 2090-6420
Text
8261985.pdf - Published Version
Download (317kB)
8261985.pdf - Published Version
Download (317kB)
Official URL: https://doi.org/10.1155/2020/8261985
Abstract
We report an intensive care patient who was given excessive amounts of antithrombin concentrate in response to spuriously low antithrombin activity measurements and was then treated with plasmapheresis (therapeutic plasma exchange or TPE) to remove the excess.